<LOGO>
FM Transmitter Measurement Report
Created: 2025-04-15 20-01-20
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
96.90 MHz 5/5, 56 dBuV VOLTAGE
Pilot RDS Phase Difference
6.4 kHz 4.0 kHz -8 deg
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 1,0 kHz
MIN Hold Max. Samples at Total Samples % above 76,0 kHz
10 kHz 71 kHz 10120 0,4051
Modulation Power
Limit Measuring Tolerance
10,0 dBr 0,2 dBr
MIN AVE MAX % above 10,2 dBr
5,8 dBr 7,05 dBr 8,1 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
"VOLTAGE " FE45 0 (No PTY) 1 0 0 2 20:01, 15.04.2025
RT
"VOLTAGE - Addictive Radio "
AF EON
96.9, 102.9 MHz -
FM Scope Station: 96.90 MHz, signal: 5/5 (55 dBuV) Max at: 71 kHz MIN: 10 kHz % above 76 kHz: 0,4051 Acquired: 2025/04/15 20:00:16 Total samples: 10120 Equivalent time: 0:08:26 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 1000 2000
FM Scope MAX: 8,1 dBr MIN: 5,8 dBr AVE: 7,05 dBr % above 10,2 dBr: 0,0 Last value: 8,1 dBr (2025/04/15 20:00:16) Station: 96.90 MHz, signal: 5/5 (55 dBuV) 19:53 19:54 19:55 19:56 19:57 19:58 19:59 20:00 0 50 100 Dev. MAX [kHz] 0 5 Pm [dBr] 0 5 Signal Quality